ASTM F138 PDF

ASTM Fa. Standard Specification for Wrought 18ChromiumNickel Molybdenum Stainless Steel Bar and Wire for Surgical Implants. Find the most up-to-date version of ASTM F at Engineering Mechanical values listed above are typical for uniaxial tension. Upon request, we can also deliver this material with other properties. L (ASTM F), Ti.

Author: Meztibar Tojara
Country: Cayman Islands
Language: English (Spanish)
Genre: Sex
Published (Last): 7 May 2006
Pages: 21
PDF File Size: 10.87 Mb
ePub File Size: 13.97 Mb
ISBN: 766-7-65848-459-9
Downloads: 39263
Price: Free* [*Free Regsitration Required]
Uploader: Mebei

The manufacturer shall not ship material that is outside the limits speci?

Bar and wire shall be furnished, as specified, in the hot-worked, annealed, cold -worked, or extra hard condition. Alternatively, a gage length corresponding to ISO may be used when agreed upon between supplier and purchaser. Last previous edition approved in as F — It is not warranted or guaranteed. Satm Hardness, max, HB Find out more by contacting us at Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters.

Based upon this, metallurgical requirements include? Approved June 10, On the other hand, types of finish available for fine wire products are cold-drawn, ground, and ground and polished.

LS / LVM Surgical Stainless Steel Bar – ASTM F

Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm. Due to the atm characterized level of local biological response established by this material, it has been used as a control material in Practice F It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application.

  CATHY COOTE PDF

A number in parentheses indicates the year of last reapproval. Users aztm this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. If you feel that your comments have not received a fair hearing you should make ashm views known to the ASTM Committee on Standards, at the address shown below.

316LS / 316LVM Surgical Stainless Steel Bar – ASTM F138

C Typically supplied as hot-rolled bar for forging applications. This specification covers the requirements for wrought 18chromiumnickel Advanced ladle metallurgy allows for fine adjustments of the composition, amount, size, shape and distribution of the nonmetallic inclusions normally occurring within standard stainless steel.

A superscript epsilon e indicates an editorial change since the last revision or reapproval. Current edition approved June 10, C Cold-drawn wire may be ordered qstm tensile strengths up to psi MPa with lower elongation as determined by customer and supplier. Analysis for elements not listed in Table 3 is not required to certify compliance with this speci? Materials and Manufacture 5.

While most manufacturers quickly turn to material costs as a primary means of lowering their price, these short-term accommodations are not always sustainable. General Requirements for Delivery 3. The level of mechanical properties for material in conditions other than those included v138 Table 1 and Table 2, shall be speci?

  DESCARGAR LIBRO MADUREZ ESCOLAR MABEL CONDEMARIN PDF

Different tests shall be performed in order to determine the following mechanical properties of the wire and bar: ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

Recommended crosshead speed for cold-drawn?

F — 03 Standard Speci? F Specification for Wrought 18ChromiumNickel The SI units given in parentheses are for information only. This standard has been approved for use by agencies of the Department of Defense.

Billet shall also be ultrasonically tested prior to being hot rolled and should be free of internal defects. Work Item s – proposed revisions of this standard. The alloy is nonmagnetic even after severe cold forming operations.

LVM ASTM F – BME Encyclopedia

The outcome equals considerably longer tool life, increased productivity, better chip breaking, better dimensional tolerances, superior machined surface quality, reduced scrap losses, and consistent performance which translates to a reliable production schedule. Link to Active This link will always route to the current Active version of the standard. This abstract is a brief summary of the referenced standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.