BRONICA SQ-A MANUAL PDF

Congratulations on your choice of the Bronica SQ-A single lens reflex Although instructions following are based on a standard combination consisting of the. View and Download BRONICA SQ-A manual online. SQ-A Digital Camera pdf manual download. View and Download Zenza Bronica SQ-A instructions manual online. Zenza Bronica SQ-A Single lens Reflex Camera. SQ-A Film Camera pdf manual download.

Author: Mezigul Kagagore
Country: Malawi
Language: English (Spanish)
Genre: Automotive
Published (Last): 13 March 2006
Pages: 13
PDF File Size: 19.94 Mb
ePub File Size: 10.29 Mb
ISBN: 456-1-85850-794-7
Downloads: 77485
Price: Free* [*Free Regsitration Required]
Uploader: Dairisar

To obtain best results from the Zenza Bronica SQ-Am, may we suggest that you read this instruction manual through carefully, before you even touch the camera, as your pleasure in using the camera will be even greater if you thoroughly familiarize eq-a self with its working parts before loading your first roll of film.

This means, of course, that flash fill-in for daylight shots can also be made very easily. Although the Zenza Bronica SQ-Am has been designed exclusively for motorized operations, it has, also, been developed as a complete modular “system” camera possessing complete interchangeability with the interchangeable lenses and ac cessories developed for the SQ and SQ-A models, on which the SQ-Am is also based, and, therefore, provides the user with a very high degree of motorization in daily operations, in addition to automatic bronicca winding and shutter cocking actions.

Helical focusing system built into each lens. Attachment of the Neck Strap A. Comments to this Manuals Your Name. A red LED will illuminate in broniac viewfinder during shutter fire. In the following cases, the shutter will not be released and a shutter release warning LED will light up, outside the screen area, in the top center of the finder: Attach in the reverse manner.

Specifications Of Zenzanon-s Lenses This will help you keep track of the film loaded in the film back, even when two or more film backs are used with different films. Upon loading the film, rotate the film-winding crank until it stops to place the first frame into place for taking the picture.

Therefore, insert the right end of the spool on to the right-side shaft, which is fixed, and then close the left-side holder shaft which will engage the spool. Unscrew the set screw on the time exposure lever until further rev- olution is impossible, which will permit the lever to be manuzl freely.

  C106M DATASHEET PDF

When the mode selector switch is set to Sm, the film will be advanced one frame and the shutter will be cocked, after which motor operation will be suspended, each time the shutter release button is depressed and the picture taken. Mirror lock-up possible with the mirror lock-up switch lever on the camera main body, with.

Should new film be loaded and the drive button depressed, with the mirror lock-up switch lever at C, the film will be placed into position for exposing the first frame with the mirror locked up. Batteries for motor drive operation does not have sufficient power. All interchangeable lenses for the Zenza Bronica SQ-A have fully automatic lens diaphragms, which means that the focusing screen is always viewed at the full aperture, with the brightest possible image.

This camera manual library is for reference and historical purposes, all rights reserved. Lens diaphragm Fully automatic instant reopening lens diaphragm action; equal-distant aperture scale graduations. Use lens cleaning tissue and liquid to clean the surface of the lens.

Zenza Bronica SQ-A Instructions Manual

After focusing in the normal manner, re-set the distance indicated by the orange colored distance index to the infrared index, by shifting the distance ring.

Attachment and Removal of Film Backs If winding is not possible, all preparations for taking pictures have been completed. After loading the fresh film spool properly, draw bronicca the leading end of the film and turn it across the film pressure plate as illustrated.

To obtain best results from your camera, we suggest that you read this instruction manual. Distance Scale and Depth of Field Scale. Click here to see different screens.

Bronica SQ – – The free camera encyclopedia

Use the above address for a check, M. The exposure counter shows the number of frames sqa- or, in other words, is an additive type. When replacing the batteries, replace all six batteries at the same time. Thus, it’s always possible to choose the film type most suited for the shot, even midway in the roll. Mode changes with mode selector switch on the handgrip, with three settings.

  CISCO 3745 DATASHEET PDF

First, insert the U-shaped ring into the nronica strap eyelet, as illustrated.

Personal tools Log in. This page is copyright byM. The six AA- size batteries for the motor drive system must be loaded in the battery holder taken out, with their polarity marks coincided to the indications on the holder. Standard type, supplied with camera, has split-image rangefinder spot surrounded by microprism ring and full-area matte screen.

The drive button should be used, in this case, to advance the film one frame. Therefore, continue rotating the film-winding crank until the remaining film and all leader paper is wound up on the take-up spool.

Functions on the Hand-Grip. Set the mode selector switch to OFF.

Intermediate settings are also possible. See Bronica lenses for a list. First, return the mirror lock-up Then, mmanual it dry with a soft, dry cloth. This page has been accessed 59, times. Minimum manuzl distance M.

Use a smooth, gentle Use a smooth, gentle action and press all the way in, without using strength or jerking. The T mode will function on lenses equipped as such.

Auto-Winding and Shutter Cocking. Next, thread the neck strap through the plastic ring cover and the U-shaped ring and pull it out, as illustrated. Simply rotate the magnifier frame in the counter-clockwise direction to unscrew. When C is set to the index, with the bronics lock-up switch lever, however, the lever will not return bronuca N with the next film advancing and shutter cocking action but will stay locked up any number of times.

Distance scales on the Zenzanon-S lenses can be used for focusing at the required distance or finding the distance actually focused. On the other hand, should the drive button be depressed when a film back is attached with film advanced properly and, there fore, in condition for photo graphy, the film will not be ad vanced.